Model Dga2013-1 Oil Dissolved Gas Tester, CE& ISO Standard, Reasonable Price
Basic Info
Model No.: Model DGA2013-1
Product Description
Model NO.:Model DGA2013-1 Colour:Any
Model DGA2013-1 Transformer Oil Dissolved Gas Analyzer, CE& ISO standard
I.Introduction:
DGA2013-1 Power system Dedicated Insulation Oil and Gas Chromatography Analysis System Manual runs by computer automatic control, all-keyboard operation and large-screen liquid crystal display according to the requirements of power system«dissolved gas component determination in insulation oil (chromatography)» ,and is characterized by high-precision temperature control, stable and reliable performance, high sensitivity, good reproducibility and so on.
The analyzer adopts double-pillar parallel shunt system ,equipped with TCD, double FID and methane conversion oven, and could achieve total analysis of nine components (H2,O2,N2,CH4,C2H2,C2H4,C2H6,CO, CO2)of dissolved gas in insulation oil by one time.
The analyzer can be employed for internal fault detection of power system oil and gas equipments, cooling medium analysis of hydrogen-cooled generators, impurity analysis of sulfur hexafluoride, the boiler flue gas analysis, gas analysis and environmental monitoring analysis. Due to its employment not only for special analysis, but also for general analysis, the analyzer becomes the most effective gas analytical instrument in petroleum, chemical engineering, mining and other systems.
1.Main technical specification
1.1Temperature control
Temperature range
Column chamber: room temperature+15ºC—399ºC
Vaporizing chamber: room temperature+30ºC—399ºC
Conversion furnace :room temperature+30ºC—399ºC
Thermal conductivity detector: room temperature+30ºC—399ºC
Hydrogen flame detector :room temperature+30ºC—399ºC
Temperature control precision: ±0.1ºC
1.2 Thermal conductivity detector
Sensitivity: minimum detectable concentration of hydrogen≥5μl/L
Noise: ≤0.05mv
Drift: ≤0.15mv/30min
1.3 Hydrogen flame detector
Minimum detectable concentration of hydrocarbon≥5μl/L
Minimum detectable concentration of CO,CO2≥5μl/L
Noise: ≤0.05mv
Drift: ≤0.15mv/30min
1.4 Whole machine start-up time: less than 3 hours
2.Main performance characteristics
2.1 Computer-keyboard operation
This realizes five heating zone temperature control, detector control, over-temperature protection, "zero" degree protection, air break protection and other functions, so as to protect the chromatographic column and thermal conductivity rhenium tungsten filament most effectively.
2.2 Large-screen liquid crystal display
It could display a large amount of information intuitively and clearly.
2.3 Advanced chromatography process
Based on only one injection and three-detectors analytical process, the analyzer greatly increases detection sensitivity of hydrocarbon gas. Double hydrogen flame setting also reduces the detection impact caused by the gas content differences.
3.Working conditions
3.1 Normal instrument working conditions
Environmental condition:5ºC—35ºC
Relative Humidity:≤80%
Power supply:220V±10% 50Hz±0.5Hz
3KW power provided.
No strong electromagnetic interference, corrosive gas and strong shock in the surroundings.
3.2 Gas source
Air purity: ensure the purity of carrier gas and hydrogen is more than 99.99%, the air to be used is purified and air generator function in dust, oil and water removal.
Output pressure of steel cylinder relief valve: nitrogen 0.35MPa, hydrogen 0.25MPa, air 0.35MPa
Please replace steel cylinder timely when output pressure fell below 2MPa.
3.3 Ground wire
To ensure personal safety and instrument performance, the instrument must be reliably linked to the land. It is suggested to bury the ground wire in the soil 1 meter below.
Contact us if you need more details on Oil Tester. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Lab Equipment、Test Equipment. If these products fail to match your need, please contact us and we would like to provide relevant information.
Model DGA2013-1 Transformer Oil Dissolved Gas Analyzer, CE& ISO standard
I.Introduction:
DGA2013-1 Power system Dedicated Insulation Oil and Gas Chromatography Analysis System Manual runs by computer automatic control, all-keyboard operation and large-screen liquid crystal display according to the requirements of power system«dissolved gas component determination in insulation oil (chromatography)» ,and is characterized by high-precision temperature control, stable and reliable performance, high sensitivity, good reproducibility and so on.
The analyzer adopts double-pillar parallel shunt system ,equipped with TCD, double FID and methane conversion oven, and could achieve total analysis of nine components (H2,O2,N2,CH4,C2H2,C2H4,C2H6,CO, CO2)of dissolved gas in insulation oil by one time.
The analyzer can be employed for internal fault detection of power system oil and gas equipments, cooling medium analysis of hydrogen-cooled generators, impurity analysis of sulfur hexafluoride, the boiler flue gas analysis, gas analysis and environmental monitoring analysis. Due to its employment not only for special analysis, but also for general analysis, the analyzer becomes the most effective gas analytical instrument in petroleum, chemical engineering, mining and other systems.
1.Main technical specification
1.1Temperature control
Temperature range
Column chamber: room temperature+15ºC—399ºC
Vaporizing chamber: room temperature+30ºC—399ºC
Conversion furnace :room temperature+30ºC—399ºC
Thermal conductivity detector: room temperature+30ºC—399ºC
Hydrogen flame detector :room temperature+30ºC—399ºC
Temperature control precision: ±0.1ºC
1.2 Thermal conductivity detector
Sensitivity: minimum detectable concentration of hydrogen≥5μl/L
Noise: ≤0.05mv
Drift: ≤0.15mv/30min
1.3 Hydrogen flame detector
Minimum detectable concentration of hydrocarbon≥5μl/L
Minimum detectable concentration of CO,CO2≥5μl/L
Noise: ≤0.05mv
Drift: ≤0.15mv/30min
1.4 Whole machine start-up time: less than 3 hours
2.Main performance characteristics
2.1 Computer-keyboard operation
This realizes five heating zone temperature control, detector control, over-temperature protection, "zero" degree protection, air break protection and other functions, so as to protect the chromatographic column and thermal conductivity rhenium tungsten filament most effectively.
2.2 Large-screen liquid crystal display
It could display a large amount of information intuitively and clearly.
2.3 Advanced chromatography process
Based on only one injection and three-detectors analytical process, the analyzer greatly increases detection sensitivity of hydrocarbon gas. Double hydrogen flame setting also reduces the detection impact caused by the gas content differences.
3.Working conditions
3.1 Normal instrument working conditions
Environmental condition:5ºC—35ºC
Relative Humidity:≤80%
Power supply:220V±10% 50Hz±0.5Hz
3KW power provided.
No strong electromagnetic interference, corrosive gas and strong shock in the surroundings.
3.2 Gas source
Air purity: ensure the purity of carrier gas and hydrogen is more than 99.99%, the air to be used is purified and air generator function in dust, oil and water removal.
Output pressure of steel cylinder relief valve: nitrogen 0.35MPa, hydrogen 0.25MPa, air 0.35MPa
Please replace steel cylinder timely when output pressure fell below 2MPa.
3.3 Ground wire
To ensure personal safety and instrument performance, the instrument must be reliably linked to the land. It is suggested to bury the ground wire in the soil 1 meter below.
Contact us if you need more details on Oil Tester. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Lab Equipment、Test Equipment. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Petroleum Products Testing Equipment
Premium Related Products
Other Products
Hot Products
Rapeseed Frying Machine/ Oil Crops Seeds Roaster Machine/Nuts Roaster MachineScrew Conveyor Screw Elevator Machine for Oil MakingHighly Effective Centrifugal Subside Oil Residue Seperator Oil FilterDirty Deep Fried Oil, Vegetable Oil Processing Machine (COP)Top Highly Recommended Automatic Black Waste Car Oil Distillation Renewing Plant (EOR)Zero Pollution Waste Turbine Oil Water Separator SystemGreen Waste Hydraulic Oil Filtration SystemFully Automatic Transformer Oil Bdv Measuring Instruments (iij-II)Peant Oil Filter Machine Cooking Oil Vacuum Filter (YLJZ 50-1/2)on-Site Fully Automatic High Vacuum Transformer Oil Purifier (ZYD-100)Plate Flame Filter (YBLL)Temperature Control Oil Press Yzyx120wk10tons Per Day Hand-Operated Screw Oil Press Yzyx140Portable Oil Press Automatic Seed Oil Expeller with 100L Oil Press Filter250L/Hr Oil Refinery Machine for Peanut Oil RefineryFull Automatic Oil Press Machine with Frying and Oil Filter